ABC Cable (3+1+2 Core)
Low Voltage ABC Cable (3+1+2 Core)

ABC Cable (3+1+2 Core)

ZD CABLE’s Aerial Bounded Cable (ABC) is primarily used for overhead power lines. It is an excellent choice for supplying electricity to street lights, outdoor lighting systems, and temporary power for construction sites. ABC cable is designed to operate safely at a voltage of 0.6/1kV and can withstand outdoor weather conditions.

Features:

  • Includes 3 phase wires, 1 neutral wire, and 2 dedicated wires for street lighting in a single bundle.
  • Uses All Aluminum Conductors (AAC) for phase and lighting, and All Aluminum Alloy Conductors (AAAC) for the neutral wire to increase strength.

ZD CABLE offers a Aerial Bounded Cable (ABC) designed for overhead power networks. The specific cable features a “3+1+2” configuration, making it highly efficient for urban areas.

  • 3 Phase Conductors:ย Made of circular compacted aluminum (AAC).
  • 1 Neutral Conductor:ย Made of circular compacted aluminum alloy (AAAC) for extra support.
  • 2 Public Lighting Conductors:ย Made of aluminum (AAC) specifically to power street lights.

Every wire in this bundle is covered with black Cross-linked polyethylene (XLPE) insulation. The insulation is strong and protects the wires from weather damage and sunlight (UV rays). The cable is rated for 0.6/1kV and works safely at temperatures up to 90ยฐC.

Standards:

  • NF C 33-209 Insulated Cable Assembled with Harness for Overhead Network, with Rated Voltage of 0.6/1kV.
No. of Cores and Section (mmยฒ) No. of Wires (No.) Nominal Insulation Thickness (mm) Aprrox. Diameter of Cable (mm) Max. DC. Resistance at 20ยฐC (ฮฉ/km) Aprrox. Weight (kg/km)
2×16 7 1.2 14.4 1.91 131
2×25 7 1.4 17.6 1.20 200
2×35 7 1.6 20.4 0.868 273
2×50 7 1.6 22.6 0.641 350
2×70 12 1.8 26.8 0.443 495
2×95 19 1.8 30.4 0.320 656
2×120 19 1.8 32.8 0.253 799
4×16 7 1.2 17.4 1.91 262
4×25 7 1.4 21.3 1.20 399
4×35 7 1.6 24.7 0.868 547
4×50 7 1.6 27.3 0.641 699
4×70 12 1.8 32.4 0.443 990
4×95 19 1.8 36.8 0.320 1311
4×120 19 1.8 39.7 0.253 1597

No. of Cores and Section (mmยฒ) No. of Wires (Phase) (No.) No. of Wires (Neutral) (No.) Nominal Insulation Thickness (Phase) (mm) Nominal Insulation Thickness (Neutral) (mm) Approx. Diameter of Cable (mm) Max. DC. Resistance at 20ยฐC (Phase) (ฮฉ/km) Max. DC. Resistance at 20ยฐC (Neutral) (ฮฉ/km) Approx. Weight (kg/km)
1×25+1×54.6 7 7 1.4 1.6 21.3 1.20 0.63 309
1×35+1×54.6 7 7 1.6 1.6 22.7 0.868 0.63 345
1×50+1×54.6 7 7 1.6 1.6 23.8 0.641 0.63 384
1×70+1×54.6 12 7 1.8 1.6 25.9 0.443 0.63 456
1×95+1×54.6 19 7 1.8 1.6 27.7 0.320 0.63 537
1×70+1×70 12 7 1.8 1.6 26.7 0.443 0.50 491
1×95+1×70 19 7 1.8 1.6 28.5 0.320 0.50 571
1×120+1×70 19 7 1.8 1.6 29.7 0.253 0.50 643
1×120+1×95 19 19 1.8 1.6 31.9 0.253 0.343 737
1×150+1×95 19 19 1.8 1.6 33.6 0.206 0.343 819
3×25+1×54.6 7 7 1.4 1.6 23.5 1.20 0.63 508
3×35+1×54.6 7 7 1.6 1.6 26.1 0.868 0.63 619
3×50+1×54.6 7 7 1.6 1.6 28.1 0.641 0.63 733
3×70+1×54.6 12 7 1.8 1.6 31.9 0.443 0.63 951
3×95+1×54.6 19 7 1.8 1.6 35.2 0.320 0.63 1192
3×70+1×70 12 7 1.8 1.6 32.4 0.443 0.50 986
3×95+1×70 19 7 1.8 1.6 35.6 0.320 0.50 1227
3×120+1×70 19 7 1.8 1.6 37.8 0.253 0.50 1441
3×120+1×95 19 19 1.8 1.6 39.1 0.253 0.343 1536
3×150+1×95 19 19 1.8 1.6 42.2 0.206 0.343 1779

No. of Cores and Section (mmยฒ) No. of Wires (Phase) (No.) No. of Wires (Neutral) (No.) No. of Wires (Public Lighting) (No.) Nominal Insulation Thickness (Phase) (mm) Nominal Insulation Thickness (Neutral) (mm) Nominal Insulation Thickness (Public Lighting) (mm) Approx. Diameter of Cable (mm) Max. DC. Resistance at 20ยฐC (Phase) (ฮฉ/km) Max. DC. Resistance at 20ยฐC (Neutral) (ฮฉ/km) Max. DC. Resistance at 20ยฐC (Public Lighting) (ฮฉ/km) Approx. Weight (kg/km)
3×25+1×54.6+1×16 7 7 7 1.4 1.6 1.2 30.1 1.20 0.63 1.91 571
3×35+1×54.6+1×16 7 7 7 1.6 1.6 1.2 32.9 0.868 0.63 1.91 682
3×50+1×54.6+1×16 7 7 7 1.6 1.6 1.2 35.1 0.641 0.63 1.91 797
3×70+1×54.6+1×16 12 7 7 1.8 1.6 1.2 39.3 0.443 0.63 1.91 1014
3×70+1×54.6+1×25 12 7 7 1.8 1.6 1.4 39.3 0.443 0.63 1.20 1049
3×70+1×70+1×16 12 7 7 1.8 1.6 1.2 40.1 0.443 0.50 1.91 1049
3×95+1×70+1×16 19 7 7 1.8 1.6 1.2 43.7 0.320 0.50 1.91 1290
3×120+1×70+1×16 19 7 7 1.8 1.6 1.2 46.1 0.253 0.50 1.91 1504
3×120+1×95+1×16 19 19 7 1.8 1.6 1.2 48.3 0.253 0.343 1.91 1598
3×150+1×95+1×16 19 19 7 1.8 1.6 1.2 51.7 0.206 0.343 1.91 1842
3×25+1×54.6+2×16 7 7 7 1.4 1.6 1.2 30.1 1.20 0.63 1.91 637
3×35+1×54.6+2×16 7 7 7 1.6 1.6 1.2 32.9 0.868 0.63 1.91 748
3×50+1×54.6+2×16 7 7 7 1.6 1.6 1.2 35.1 0.641 0.63 1.91 862
3×70+1×54.6+2×16 12 7 7 1.8 1.6 1.2 39.3 0.443 0.63 1.91 1080
3×70+1×54.6+2×25 12 7 7 1.8 1.6 1.4 39.3 0.443 0.63 1.20 1148
3×70+1×70+2×16 12 7 7 1.8 1.6 1.2 40.1 0.443 0.50 1.91 1114
3×95+1×70+2×16 19 7 7 1.8 1.6 1.2 43.7 0.320 0.50 1.91 1356
3×120+1×70+2×16 19 7 7 1.8 1.6 1.2 46.1 0.253 0.50 1.91 1570
3×120+1×95+2×16 19 19 7 1.8 1.6 1.2 48.3 0.253 0.343 1.91 1664
3×150+1×95+2×16 19 19 7 1.8 1.6 1.2 51.7 0.206 0.343 1.91 1907

Send Inquiry

Contact Us

+86 13703994527

Henan Zhong Dong Cable

Henan Zhong Dong Cable

Henan Zhong Dong Cable

Henan Zhong Dong Cable

Submit A Form