Standards: IEC 61089, ASTM B231, BS EN 50182, AS 1531, GB/T 1179
Key Note: In-house QC includes tensile, resistance, and wrapping checks.
Datasheet: Download (PDF)
Supporting contractors, subcontractors, engineering teams & tender support teams. Your quote, datasheet, and technical documents are built around your BOQ or spec, ready for your tender file and project delivery documents.
No full BOQ yet? Send a code or spec — we'll confirm quote timeline or missing details.
Send your BOQ or spec — we organize the quotation, respond to conductor questions, and prepare pre-PO documents before order placement.
Your quote, datasheet, and any conductor questions stay in one project thread. Follow-up questions and revisions are logged there too, so changes stay tied to confirmed datasheet details.
We organize the technical datasheet and draft PI. If a third-party report is required or requested, we confirm timing and cost separately.
We make the aluminum basis and conversion cost clear with the quote. The adjustment formula is confirmed at PO, and later changes are calculated by that formula, not reopened as new terms.
Select a product family below to view standards, key notes, and datasheet links. For code or wording not shown here, send it for review.
Standards: IEC 61089, ASTM B231, BS EN 50182, AS 1531, GB/T 1179
Key Note: In-house QC includes tensile, resistance, and wrapping checks.
Datasheet: Download (PDF)
Standards: IEC 61089, ASTM B399, BS EN 50182, AS 1531
Key Note: In-house QC includes tensile, resistance, and wrapping checks.
Datasheet: Download (PDF)
Standards: IEC 61089, ASTM B232, BS EN 50182, AS 3607, GOST 839
Key Note: In-house QC includes tensile, resistance, and wrapping checks.
Datasheet: Download (PDF)
Standards: IEC 61089, ASTM B524, GB/T 1179, GOST 839
Key Note: In-house QC includes tensile, resistance, and wrapping checks.
Datasheet: Download (PDF)
Standards: ASTM B416, AS 1222.2, GB/T 1179, GOST 839
Key Note: Capable of high-frequency communication.
Datasheet: Download (PDF)
Standards: ASTM B856, GOST 839
Key Note: High-temperature low-sag (HTLS) conductor.
Datasheet: Download (PDF)
Standards: ASTM B857, GOST 839
Key Note: Reduced drag coefficient and high capacity design.
Datasheet: Download (PDF)
Standards: ASTM B549, GB/T 1179, GOST 839
Key Note: Better corrosion resistance than standard ACSR.
Datasheet: Download (PDF)
Standards: IEC 61089, ASTM B711, GB/T 1179, GOST 839
Key Note: Al-Mg-Si alloy and steel core construction.
Datasheet: Download (PDF)
Standards: AS 3607, GOST 839
Key Note: High tensile strength with excellent conductivity.
Datasheet: Download (PDF)
Standards: NB/T 42060, GOST 839
Key Note: Operates at higher temperatures than standard ACSR.
Datasheet: Download (PDF)
Send the code or wording from tender or project documents. Within 12 hours, we confirm listed-family match, missing details, and datasheet or quote timing.
Every production batch goes through in-house QC. Existing third-party reports are shared where available. New testing can be arranged after scope, cost, and timing are confirmed.
DC resistance from 0.01 μΩ to 200 Ω with automatic temperature correction (0–40 °C).
Tensile testing for individual aluminum strands and galvanized-steel core wires before stranding.
Wrap and torsion on aluminum strand (0–6 mm) and galvanized steel core (0–4 mm); reverse-bend on wires 0.3–10 mm.
Vision-based wire diameter, conductor OD (1–80 mm), and lay-length verification, sampled during stranding.
Finished-conductor type tests are verified by CNAS-accredited labs under ISO/IEC 17025 and the ILAC MRA framework, with reports used for tender files and project review where required.
Existing reports are shared where available. New third-party testing can be arranged after the required test scope, cost, and typical 4–8 week timing are confirmed.Sample CNAS Reports
Sample CNAS reports shown here are selected ACSR code examples, not full product-family coverage. For other conductor codes or families, we confirm whether an existing file is available, new testing can be arranged, or further review is needed.
ISO certificates cover factory management systems, not type test reports for individual conductor codes.
Send your BOQ or spec and we confirm conductor match, steel core options, drum packaging, and project marking as part of your quote.
We quote against the reference standard, conductor code, family, or size stated in your BOQ or spec. Code examples include numeric sizes and named conductors such as 240/40, 330/43, Drake, Duck, and IBIS.
Choose ACSR/AW or AACSR/AC for improved corrosion resistance, and TACSR or ACSS options to support existing-line uprating where project design allows. Final selection depends on line conditions and required standard.
Wooden, steel-wooden, and returnable steel drum options can be confirmed per order. ISPM-15 marking applies to regulated wood packaging. Single drum length is confirmed against conductor code, standard, cross-section, and project drum schedule.
Project reference, drum number, and shipping mark can be printed on each drum to support checking during loading, customs review, and site receiving.
Sealed-container shipping helps reduce salt-air exposure and corrosion risk for bare aluminum. Every drum ships in a sealed 20'GP, 40'GP, or 40'HQ. Never open-top or flat-rack.
Before sealing, we send drum-by-drum photos showing bracing, drum orientation, your project reference, and ISPM-15 marking where regulated wood packaging requirements apply.
We send shipment updates at five key milestones, so status checks do not depend on back-and-forth follow-up. The applicable Incoterm and payment details are confirmed through the quote and PO process.
Milestone updates we push to you
Engineers review your submission and reply with a datasheet, price basis, and validity window, ready to attach to your client's file.
Your project details are kept confidential and are never shared with your end client.