Wholesale ABC Cable
Factory-Direct Manufacturer LV Aerial Bundled Cable for Utilities, EPC Contractors & Distributors · NF C33-209 / IEC 60502 · 16–150 mm²

0.6/1 kV
5 Cores
16–150 mm²
XLPE
NF C33-209
IEC 60502-1
Both standards supported · Same product line · Africa, SE Asia & International markets
Wholesale Supply OEM Available Source Factory Trade Sample on Request
  • No Standards Mismatch — Dual NF C33-209 / IEC 60502-1 Compliance, One Product Line.
  • No Field Failures — XLPE Weather-Sealed, 30-Year Service Life Even in UV-Heavy Coastal Climates.
  • No Supply Surprises — In-House Production, 15–60 Day Delivery, MOQ from 1000 m.
Response within 3 hours during business hours.
ABC Cable NF C33-209 / IEC 60502
ABC Cable 3+1 Core NF C33-209 / IEC 60502 — Wholesale Supply for Utilities & EPC Contractors in Africa & SE Asia
Factory Direct
MOQ: 1000 m
15–60 Day Delivery
OEM & Custom Spec

ABC Cable Manufacturing — NF C33-209 & IEC 60502-1 Compliant Production

Wholesale Source-Factory Production for Utilities, EPC Contractors & Distributors. We match your tender drawings — NFC, IEC, or other international standards.

Tender-Spec Production: Manufactured to your tender drawings, technical data sheets and customer-supplied specs — no off-the-shelf compromise.

Dual-Standard Lines: NF C33-209 (French / African market) and IEC 60502-1 (international) production lines running in parallel — same factory, same QA team.

Conductor & Insulation: Class 2 compacted aluminum conductor (AAC for phase, AAAC for messenger), weather-resistant black XLPE insulation rated to 90 °C.

ABC Cable Cross-Section by Core Configuration Compare 2-Core, 4-Core, 1+1, 3+1, 3+1+1 and 3+1+2 ABC cable structures
L1 L2 Phase ID Ribs1 rib = L1, 2 ribs = L2 Aluminum ConductorStranded, circular compacted AAC XLPE InsulationBlack, weather & UV resistant L1 L2 L3 N Equal-Core DesignAll 4 conductors identical size XLPE InsulationAll cores insulated, black Neutral (N)Same cross-section as phase L1 MSG Insulated Phase (×1)XLPE insulated aluminum Messenger / NeutralAAAC load-bearing, insulated Unequal-Core LayoutPhase and neutral differ in size MSG L1 L2 L3 Phase Conductor (×3)XLPE insulated, compacted aluminum Messenger / NeutralAAAC, compacted, insulated Left-Hand Lay BundlePhase cores twisted around messenger MSG L1 L2 L3 SL Phase Conductor (×3)XLPE insulated aluminum Street Lighting ×116 or 25mm², XLPE insulated Messenger / NeutralAAAC load-bearing Pilot Wire (optional)Solid copper 1.5mm² MSG L1 L2 L3 SL1 SL2 Phase Conductor (×3)XLPE insulated aluminum Street Lighting ×2Dual public lighting circuits Messenger / NeutralAAAC load-bearing
NF C33-209 IEC 60502-1

All 6 ABC cable configurations available under NF C33-209 and IEC 60502-1. Click tabs to compare cross-sections and specifications.

ABC Cable Sizes & Specifications 2-Core Equal — All cores same cross-section, 16 mm² to 120 mm²
2-Core Equal ABC Cable Specifications — NF C33-209 / IEC 60502 Compliant Sizes from 2×16 mm² to 2×120 mm²
ConfigurationWires
No.
Insul.
mm
OD
mm
DC Resist.
Ω/km
Weight
kg/km
2×1671.214.41.91131
2×2571.417.61.20200
2×3571.620.40.868273
2×5071.622.60.641350
2×70121.826.80.443495
2×95191.830.40.320656
2×120191.832.80.253799
4-Core Equal ABC Cable Specifications — NF C33-209 / IEC 60502 Compliant Sizes from 4×16 mm² to 4×120 mm²
ConfigurationWires
No.
Insul.
mm
OD
mm
DC Resist.
Ω/km
Weight
kg/km
4×1671.217.41.91262
4×2571.421.31.20399
4×3571.624.70.868547
4×5071.627.30.641699
4×70121.832.40.443990
4×95191.836.80.3201311
4×120191.839.70.2531597
1+1 ABC Cable Specifications — 1 Phase plus Messenger / Neutral, NF C33-209 / IEC 60502 Compliant, sizes from 1×25+1×54.6 to 1×150+1×95 mm²
ConfigurationPhase
Wires
Neutral
Wires
Insul. Ph
mm
Insul. N
mm
OD
mm
Resist. Ph
Ω/km
Resist. N
Ω/km
Weight
kg/km
1×25+1×54.6771.41.621.31.200.63309
1×35+1×54.6771.61.622.70.8680.63345
1×50+1×54.6771.61.623.80.6410.63384
1×70+1×54.61271.81.625.90.4430.63456
1×95+1×54.61971.81.627.70.3200.63537
1×70+1×701271.81.626.70.4430.50491
1×95+1×701971.81.628.50.3200.50571
1×120+1×701971.81.629.70.2530.50643
1×120+1×9519191.81.631.90.2530.343737
1×150+1×9519191.81.633.60.2060.343819
3+1 ABC Cable Specifications — 3 Phase plus Messenger / Neutral, NF C33-209 / IEC 60502 Compliant, sizes from 3×25+1×54.6 to 3×150+1×95 mm²
ConfigurationPhase
Wires
Neutral
Wires
Insul. Ph
mm
Insul. N
mm
OD
mm
Resist. Ph
Ω/km
Resist. N
Ω/km
Weight
kg/km
3×25+1×54.6771.41.623.51.200.63508
3×35+1×54.6771.61.626.10.8680.63619
3×50+1×54.6771.61.628.10.6410.63733
3×70+1×54.61271.81.631.90.4430.63951
3×95+1×54.61971.81.635.20.3200.631192
3×70+1×701271.81.632.40.4430.50986
3×95+1×701971.81.635.60.3200.501227
3×120+1×701971.81.637.80.2530.501441
3×120+1×9519191.81.639.10.2530.3431536
3×150+1×9519191.81.642.20.2060.3431779
3+1+1 ABC Cable Specifications — 3 Phase plus Messenger plus 1 Street Lighting Conductor, NF C33-209 / IEC 60502 Compliant
ConfigurationPh
Wires
N
Wires
SL
Wires
Ins.Ph
mm
Ins.N
mm
Ins.SL
mm
OD
mm
R.Ph
Ω/km
R.N
Ω/km
R.SL
Ω/km
Wt.
kg/km
3×25+54.6+167771.41.61.230.11.200.631.91571
3×35+54.6+167771.61.61.232.90.8680.631.91682
3×50+54.6+167771.61.61.235.10.6410.631.91797
3×70+54.6+1612771.81.61.239.30.4430.631.911014
3×70+54.6+2512771.81.41.239.30.4430.631.201049
3×70+70+1612771.81.61.240.10.4430.501.911049
3×95+70+1619771.81.61.243.70.3200.501.911290
3×120+70+1619771.81.61.246.10.2530.501.911504
3×120+95+16191971.81.61.248.30.2530.3431.911598
3×150+95+16191971.81.61.251.70.2060.3431.911842
3+1+2 ABC Cable Specifications — 3 Phase plus Messenger plus 2 Street Lighting Conductors, NF C33-209 / IEC 60502 Compliant
ConfigurationPh
Wires
N
Wires
SL
Wires
Ins.Ph
mm
Ins.N
mm
Ins.SL
mm
OD
mm
R.Ph
Ω/km
R.N
Ω/km
R.SL
Ω/km
Wt.
kg/km
3×25+54.6+2×167771.41.61.230.11.200.631.91637
3×35+54.6+2×167771.61.61.232.90.8680.631.91748
3×50+54.6+2×167771.61.61.235.10.6410.631.91862
3×70+54.6+2×2512771.81.61.239.30.4430.631.201148
3×70+70+2×1612771.81.61.240.10.4430.501.911114
3×95+70+2×1619771.81.61.243.70.3200.501.911356
3×120+70+2×1619771.81.61.246.10.2530.501.911570
3×120+95+2×16191971.81.61.248.30.2530.3431.911664
3×150+95+2×16191971.81.61.251.70.2060.3431.911907

All sizes compliant with NF C33-209 & IEC 60502-1. Custom sizes & OEM packaging available — request technical data sheet.

Request Wholesale ABC Cable Quote

We match your tender drawings — NF C33-209, IEC 60502-1, or your customer-supplied spec.

CNAS Laboratory Test Report

Independently tested by Shanghai National Center of Testing and Inspection for Electric Cable and Wire — view inline or download.

0.6/1kV ABC Cable 4×120mm² — HD 626 & IEC 60811 Test Report Report No. CT25-05202 · Tested Nov–Dec 2025 · All items passed
CNAS Accredited
HD 626 / IEC 60811-605:2012
CNAS Test Report cover — 0.6/1kV ABC Cable 4×120
View Report

Verified Test Items Include:

Conductor Construction, Diameter & Lay Direction
Insulation Thickness, Diameter & Laying-up Direction
DC Resistance at 20°C & High Voltage Test (AC 4kV, 5min)
Insulation Resistance Constant Ki (80°C)
Tensile Strength, Elongation, Hot Set & Shrinkage Test
Carbon Black Content & Conductor Breaking Force
All tested items received a "P" (Pass) verdict per HD 626 & IEC 60811-605:2012.
Download PDF

ABC Cable Technical Performance

Weather & UV Resistance

XLPE insulation with carbon black withstands -40°C to +90°C, prolonged UV and tropical humidity.

Reduced Power Loss

Bundled design cuts line reactance by up to 60% vs separated bare conductors.

Enhanced Safety

Insulated cores eliminate accidental contact risk — fault rate reduced 4–6× vs bare lines.

Easy Installation

No cross-arms needed. 50% narrower corridor than bare overhead lines, wall-mountable.

General Technical Data
Rated Voltage 0.6/1 kV
Conductor Material Compacted Aluminum (AAC / AAAC)
Insulation Material XLPE, Black, Weather & UV Resistant
Max. Operating Temp. 90°C (XLPE)
Short-Circuit Temp. 250°C (max 5s)
Min. Installation Temp. -20°C
Min. Bending Radius 4D (OD<25mm) / 6D (OD≥25mm)
Standards NF C33-209 · IEC 60502-1
Pilot Wire (optional) Solid Copper 1.5mm²
Get ABC Cable Quote Now
Free Sample Available Custom Configuration Supported

Certifications & Quality Assurance

Certified Management Systems & Qualifications
ISO 9001 Certificate
ISO 9001 Quality Management System
ISO 14001 Certificate
ISO 14001 Environmental Management
ISO 45001 Certificate
ISO 45001 Occupational Health & Safety
CNAS Laboratory Accreditation
CNAS Accredited Laboratory
ILAC-MRA Mutual Recognition
ILAC-MRA Mutual Recognition Arrangement
State Grid Qualified Supplier
State Grid Qualified Supplier
Compliance Documentation
PASS PDF
Full Type Test Report

Complete electrical & mechanical test data per ASTM B232

PASS PDF
Routine Test Certificate

Batch-level inspection data issued per production order

PASS PDF
ISO Certificate Copies

Ready-to-submit certification documents for tender bids

Full Type Test Reports Available — All documentation ready for immediate provisioning upon order confirmation.
Pre-shipment inspection (PSI) coordination During-production inspection (DPI) support Factory audit & witness testing available
Get Quote + Compliance Docs

Global Project References

ZD Cable's conductors and power cables are powering grid infrastructure across Africa, Southeast Asia, Europe, and beyond. Here are some of our recent deliveries.

Overhead conductor shipment to Mozambique for grid expansion Africa

Overhead Conductor Supply for Mozambique Grid Expansion

Mozambique March 2026 Multi-Product

Supplied a full range of overhead conductors — including ACSR, ABC Cable, and HDBC bare conductors — for grid expansion and rural electrification projects. All products manufactured to IEC and BS standards with CNAS-verified test reports. UV-resistant coatings applied for tropical climate durability.

IEC & BS Compliant CNAS Test Reports Tropical UV Coating Fumigated Export Drums
1000km AAC conductor export to Vietnam Southeast Asia

1,000 KM Bare Conductor Export to Vietnam — 25 Day Production

Vietnam December 2025 AAC Conductor

Completed production and delivery of 1,000 kilometers of All Aluminum Conductor (AAC) for overhead transmission and distribution lines in just 25 days — demonstrating ZD Cable's large-scale production capability for urgent infrastructure timelines. Manufactured to IEC, ASTM, and EN standards.

1,000 km Volume 25-Day Turnaround IEC/ASTM/EN Standards Full QA Documentation
Multi-product cable shipment to Myanmar power grid Southeast Asia

Multi-Product Cable Supply for Myanmar Power Grid

Myanmar March 2026 ABC · SAC · AW-OC · 12kV

Delivered a comprehensive cable package for Myanmar's power sector — including ABC Cable for urban electrification, SAC Cable for overhead networks, AW-OC Cable for weather resistance, and 12kV power cable for industrial transmission. All cables engineered for Southeast Asia's tropical climate conditions.

4 Product Categories Climate-Adapted Design Full QA Inspection ISO 780 Export Packaging
Armored power cable shipment to Albania Europe

Armored Power Cables Shipped to Support Albanian Infrastructure

Albania December 2025 Armored Cable

Shipped armored low-voltage power cables from Qingdao port to Albania for industrial and underground infrastructure applications. Featuring copper conductors with XLPE insulation, PVC outer sheath, and Aluminum Wire Armour (AWA) layer for direct burial and demanding industrial environments.

Cu/XLPE/AWA/PVC Direct Burial Rated European Market Pre-Shipment QA

Company Introduction - ZD CABLE

0
Factory Area
0km
Annual Capacity
0+
Export Destinations
0+
Partner Units

International Manufacturing Standards

Standardized for Global Tenders: NF C33-209, IEC 60502-1, HD 626, AS/NZS 3560.1, SANS 1418-2 compliant for LV ABC Cable.
One-stop Compliance: Tailored ABC Cable solutions matching utility and EPC tender drawings across Africa, Southeast Asia, and Latin America.

Specialized Production Lines

Dedicated Production Flow: Independent lines for rod drawing, stranding, and cabling.
Process Stability: Routine in-line checks ensure consistent output.

Systematic Quality Testing

In-house Test Center: Full mechanical and electrical verification before delivery.
Batch-Level Assurance: Inspected to ISO 9001 and State Grid protocols.

ZD Cable factory stranding machine producing aluminum conductor for ABC cable, with a finished reel of black insulated ABC cable visible in the background
Close-up of the raised ridge on the black XLPE insulation of an ABC cable conductor at ZD Cable's factory
Talk to Our Sales Engineer

Direct factory contact. No middleman.

Packaging & Shipment Preparation

Order-to-Delivery Workflow
01 Spec Lock
02 Production + QA
03 Packing & Customs
04 Dispatch Tracking
Pre-Shipment Document Pack
  • Commercial Invoice & Packing List
  • Bill of Lading / Waybill
  • Certificate of Origin (if required)
  • Routine / Type Test Report Copy
  • Inspection Record (third-party on request)
Delivery Capability

Delivery Capability & Commitment

15-90 Days Production Lead Time

From order confirmation to ready-for-shipment — standard ACSR Pelican specifications

24h Order Response
100% Loading Proof
Weekly Transit Update
Order-to-Delivery Workflow
01
Spec Lock

Confirm conductor spec, drum length, marking & contract terms

02
Production + QA

Manufacturing and routine tests per approved datasheet

03
Packing & Customs

Export packing, loading inspection & shipping doc preparation

04
Dispatch Tracking

ETD/ETA updates & coordination until arrival

Supported Incoterms
EXW FOB CFR CIF DDP
Get Quote with Delivery Plan
Delivery Promise
  • Confirmed ETD plan

    Delivery schedule locked before mass production starts

  • Split-shipment available

    Partial dispatch option for urgent project milestones

  • Delay risk safeguard

    Warning and corrective action plan within 72 hours

Pre-Shipment Document Pack
  • Commercial Invoice & Packing List
  • Bill of Lading / Waybill
  • Certificate of Origin (if required)
  • Routine / Type Test Report Copy
  • Inspection Record (third-party on request)

Request Quotation

Fill in the specs. Get your price & technical sheet.