Wholesale ABC Cable
Factory-Direct Manufacturer
LV Aerial Bundled Cable for Utilities, EPC Contractors & Distributors · NF C33-209 / IEC 60502 · 16–150 mm²
- No Standards Mismatch — Dual NF C33-209 / IEC 60502-1 Compliance, One Product Line.
- No Field Failures — XLPE Weather-Sealed, 30-Year Service Life Even in UV-Heavy Coastal Climates.
- No Supply Surprises — In-House Production, 15–60 Day Delivery, MOQ from 1000 m.
ABC Cable Manufacturing — NF C33-209 & IEC 60502-1 Compliant Production
Wholesale Source-Factory Production for Utilities, EPC Contractors & Distributors. We match your tender drawings — NFC, IEC, or other international standards.
Tender-Spec Production: Manufactured to your tender drawings, technical data sheets and customer-supplied specs — no off-the-shelf compromise.
Dual-Standard Lines: NF C33-209 (French / African market) and IEC 60502-1 (international) production lines running in parallel — same factory, same QA team.
Conductor & Insulation: Class 2 compacted aluminum conductor (AAC for phase, AAAC for messenger), weather-resistant black XLPE insulation rated to 90 °C.
All 6 ABC cable configurations available under NF C33-209 and IEC 60502-1. Click tabs to compare cross-sections and specifications.
| Configuration | Wires No. | Insul. mm | OD mm | DC Resist. Ω/km | Weight kg/km |
|---|---|---|---|---|---|
| 2×16 | 7 | 1.2 | 14.4 | 1.91 | 131 |
| 2×25 | 7 | 1.4 | 17.6 | 1.20 | 200 |
| 2×35 | 7 | 1.6 | 20.4 | 0.868 | 273 |
| 2×50 | 7 | 1.6 | 22.6 | 0.641 | 350 |
| 2×70 | 12 | 1.8 | 26.8 | 0.443 | 495 |
| 2×95 | 19 | 1.8 | 30.4 | 0.320 | 656 |
| 2×120 | 19 | 1.8 | 32.8 | 0.253 | 799 |
| Configuration | Wires No. | Insul. mm | OD mm | DC Resist. Ω/km | Weight kg/km |
|---|---|---|---|---|---|
| 4×16 | 7 | 1.2 | 17.4 | 1.91 | 262 |
| 4×25 | 7 | 1.4 | 21.3 | 1.20 | 399 |
| 4×35 | 7 | 1.6 | 24.7 | 0.868 | 547 |
| 4×50 | 7 | 1.6 | 27.3 | 0.641 | 699 |
| 4×70 | 12 | 1.8 | 32.4 | 0.443 | 990 |
| 4×95 | 19 | 1.8 | 36.8 | 0.320 | 1311 |
| 4×120 | 19 | 1.8 | 39.7 | 0.253 | 1597 |
| Configuration | Phase Wires | Neutral Wires | Insul. Ph mm | Insul. N mm | OD mm | Resist. Ph Ω/km | Resist. N Ω/km | Weight kg/km |
|---|---|---|---|---|---|---|---|---|
| 1×25+1×54.6 | 7 | 7 | 1.4 | 1.6 | 21.3 | 1.20 | 0.63 | 309 |
| 1×35+1×54.6 | 7 | 7 | 1.6 | 1.6 | 22.7 | 0.868 | 0.63 | 345 |
| 1×50+1×54.6 | 7 | 7 | 1.6 | 1.6 | 23.8 | 0.641 | 0.63 | 384 |
| 1×70+1×54.6 | 12 | 7 | 1.8 | 1.6 | 25.9 | 0.443 | 0.63 | 456 |
| 1×95+1×54.6 | 19 | 7 | 1.8 | 1.6 | 27.7 | 0.320 | 0.63 | 537 |
| 1×70+1×70 | 12 | 7 | 1.8 | 1.6 | 26.7 | 0.443 | 0.50 | 491 |
| 1×95+1×70 | 19 | 7 | 1.8 | 1.6 | 28.5 | 0.320 | 0.50 | 571 |
| 1×120+1×70 | 19 | 7 | 1.8 | 1.6 | 29.7 | 0.253 | 0.50 | 643 |
| 1×120+1×95 | 19 | 19 | 1.8 | 1.6 | 31.9 | 0.253 | 0.343 | 737 |
| 1×150+1×95 | 19 | 19 | 1.8 | 1.6 | 33.6 | 0.206 | 0.343 | 819 |
| Configuration | Phase Wires | Neutral Wires | Insul. Ph mm | Insul. N mm | OD mm | Resist. Ph Ω/km | Resist. N Ω/km | Weight kg/km |
|---|---|---|---|---|---|---|---|---|
| 3×25+1×54.6 | 7 | 7 | 1.4 | 1.6 | 23.5 | 1.20 | 0.63 | 508 |
| 3×35+1×54.6 | 7 | 7 | 1.6 | 1.6 | 26.1 | 0.868 | 0.63 | 619 |
| 3×50+1×54.6 | 7 | 7 | 1.6 | 1.6 | 28.1 | 0.641 | 0.63 | 733 |
| 3×70+1×54.6 | 12 | 7 | 1.8 | 1.6 | 31.9 | 0.443 | 0.63 | 951 |
| 3×95+1×54.6 | 19 | 7 | 1.8 | 1.6 | 35.2 | 0.320 | 0.63 | 1192 |
| 3×70+1×70 | 12 | 7 | 1.8 | 1.6 | 32.4 | 0.443 | 0.50 | 986 |
| 3×95+1×70 | 19 | 7 | 1.8 | 1.6 | 35.6 | 0.320 | 0.50 | 1227 |
| 3×120+1×70 | 19 | 7 | 1.8 | 1.6 | 37.8 | 0.253 | 0.50 | 1441 |
| 3×120+1×95 | 19 | 19 | 1.8 | 1.6 | 39.1 | 0.253 | 0.343 | 1536 |
| 3×150+1×95 | 19 | 19 | 1.8 | 1.6 | 42.2 | 0.206 | 0.343 | 1779 |
| Configuration | Ph Wires | N Wires | SL Wires | Ins.Ph mm | Ins.N mm | Ins.SL mm | OD mm | R.Ph Ω/km | R.N Ω/km | R.SL Ω/km | Wt. kg/km |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 3×25+54.6+16 | 7 | 7 | 7 | 1.4 | 1.6 | 1.2 | 30.1 | 1.20 | 0.63 | 1.91 | 571 |
| 3×35+54.6+16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 32.9 | 0.868 | 0.63 | 1.91 | 682 |
| 3×50+54.6+16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 35.1 | 0.641 | 0.63 | 1.91 | 797 |
| 3×70+54.6+16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 39.3 | 0.443 | 0.63 | 1.91 | 1014 |
| 3×70+54.6+25 | 12 | 7 | 7 | 1.8 | 1.4 | 1.2 | 39.3 | 0.443 | 0.63 | 1.20 | 1049 |
| 3×70+70+16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 40.1 | 0.443 | 0.50 | 1.91 | 1049 |
| 3×95+70+16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 43.7 | 0.320 | 0.50 | 1.91 | 1290 |
| 3×120+70+16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 46.1 | 0.253 | 0.50 | 1.91 | 1504 |
| 3×120+95+16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 48.3 | 0.253 | 0.343 | 1.91 | 1598 |
| 3×150+95+16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 51.7 | 0.206 | 0.343 | 1.91 | 1842 |
| Configuration | Ph Wires | N Wires | SL Wires | Ins.Ph mm | Ins.N mm | Ins.SL mm | OD mm | R.Ph Ω/km | R.N Ω/km | R.SL Ω/km | Wt. kg/km |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 3×25+54.6+2×16 | 7 | 7 | 7 | 1.4 | 1.6 | 1.2 | 30.1 | 1.20 | 0.63 | 1.91 | 637 |
| 3×35+54.6+2×16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 32.9 | 0.868 | 0.63 | 1.91 | 748 |
| 3×50+54.6+2×16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 35.1 | 0.641 | 0.63 | 1.91 | 862 |
| 3×70+54.6+2×25 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 39.3 | 0.443 | 0.63 | 1.20 | 1148 |
| 3×70+70+2×16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 40.1 | 0.443 | 0.50 | 1.91 | 1114 |
| 3×95+70+2×16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 43.7 | 0.320 | 0.50 | 1.91 | 1356 |
| 3×120+70+2×16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 46.1 | 0.253 | 0.50 | 1.91 | 1570 |
| 3×120+95+2×16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 48.3 | 0.253 | 0.343 | 1.91 | 1664 |
| 3×150+95+2×16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 51.7 | 0.206 | 0.343 | 1.91 | 1907 |
All sizes compliant with NF C33-209 & IEC 60502-1. Custom sizes & OEM packaging available — request technical data sheet.
We match your tender drawings — NF C33-209, IEC 60502-1, or your customer-supplied spec.
CNAS Laboratory Test Report
Independently tested by Shanghai National Center of Testing and Inspection for Electric Cable and Wire — view inline or download.
Verified Test Items Include:
ABC Cable Technical Performance
Weather & UV Resistance
XLPE insulation with carbon black withstands -40°C to +90°C, prolonged UV and tropical humidity.
Reduced Power Loss
Bundled design cuts line reactance by up to 60% vs separated bare conductors.
Enhanced Safety
Insulated cores eliminate accidental contact risk — fault rate reduced 4–6× vs bare lines.
Easy Installation
No cross-arms needed. 50% narrower corridor than bare overhead lines, wall-mountable.
Certifications & Quality Assurance
Complete electrical & mechanical test data per ASTM B232
Batch-level inspection data issued per production order
Ready-to-submit certification documents for tender bids
Global Project References
ZD Cable's conductors and power cables are powering grid infrastructure across Africa, Southeast Asia, Europe, and beyond. Here are some of our recent deliveries.
Africa
Overhead Conductor Supply for Mozambique Grid Expansion
Supplied a full range of overhead conductors — including ACSR, ABC Cable, and HDBC bare conductors — for grid expansion and rural electrification projects. All products manufactured to IEC and BS standards with CNAS-verified test reports. UV-resistant coatings applied for tropical climate durability.
Southeast Asia
1,000 KM Bare Conductor Export to Vietnam — 25 Day Production
Completed production and delivery of 1,000 kilometers of All Aluminum Conductor (AAC) for overhead transmission and distribution lines in just 25 days — demonstrating ZD Cable's large-scale production capability for urgent infrastructure timelines. Manufactured to IEC, ASTM, and EN standards.
Southeast Asia
Multi-Product Cable Supply for Myanmar Power Grid
Delivered a comprehensive cable package for Myanmar's power sector — including ABC Cable for urban electrification, SAC Cable for overhead networks, AW-OC Cable for weather resistance, and 12kV power cable for industrial transmission. All cables engineered for Southeast Asia's tropical climate conditions.
Europe
Armored Power Cables Shipped to Support Albanian Infrastructure
Shipped armored low-voltage power cables from Qingdao port to Albania for industrial and underground infrastructure applications. Featuring copper conductors with XLPE insulation, PVC outer sheath, and Aluminum Wire Armour (AWA) layer for direct burial and demanding industrial environments.
Company Introduction - ZD CABLE
International Manufacturing Standards
Standardized for Global Tenders: NF C33-209, IEC 60502-1, HD 626, AS/NZS 3560.1, SANS 1418-2 compliant for LV ABC Cable.
One-stop Compliance: Tailored ABC Cable solutions matching utility and EPC tender drawings across Africa, Southeast Asia, and Latin America.
Specialized Production Lines
Dedicated Production Flow: Independent lines for rod drawing, stranding, and cabling.
Process Stability: Routine in-line checks ensure consistent output.
Systematic Quality Testing
In-house Test Center: Full mechanical and electrical verification before delivery.
Batch-Level Assurance: Inspected to ISO 9001 and State Grid protocols.
Direct factory contact. No middleman.
Packaging & Shipment Preparation
-
Commercial Invoice & Packing List
-
Bill of Lading / Waybill
-
Certificate of Origin (if required)
-
Routine / Type Test Report Copy
-
Inspection Record (third-party on request)
Delivery Capability & Commitment
From order confirmation to ready-for-shipment — standard ACSR Pelican specifications
Confirm conductor spec, drum length, marking & contract terms
Manufacturing and routine tests per approved datasheet
Export packing, loading inspection & shipping doc preparation
ETD/ETA updates & coordination until arrival
-
Confirmed ETD plan
Delivery schedule locked before mass production starts
-
Split-shipment available
Partial dispatch option for urgent project milestones
-
Delay risk safeguard
Warning and corrective action plan within 72 hours
- Commercial Invoice & Packing List
- Bill of Lading / Waybill
- Certificate of Origin (if required)
- Routine / Type Test Report Copy
- Inspection Record (third-party on request)